INTERXION LONDON

Interxion was formed in 1998 and has 20 data centre facilities across 11 countries.

Interxion are one of few data centre providers to achieve SunTone certification, ensuring quality and performance standards for their facility and services.

 

Power distribution                      Generator

Power: building power is supplied via local power company feeds and backed up with UPS (Uninterruptable Power Supply) and diesel generator backup. Diesel generators are kept pre-warmed for fast startup, with 16 hours minimum backup, and fulfillment with multiple suppliers for prolonged diesel supply. Dual individually breakered power feeds are supplied to each rack cabinet.

 

VESDA                      Argon

Fire Protection: building fit out includes VESDA (early warning smoke detection), fire-retarding walls (F60) and Argon gas fire extinguishing system.

 

24/7/365 Security                      24/7/365 Security

Security: building manned with 24/7/365 on-site security and CCTV with video archiving. Access permitted only to authorised staff and registered customer staff with photo ID. Internal access to designated floors and rooms restricted via proximity access card (PAC).

 

ESC: European Service Centre            ESC: European Service Centre

European Service Centre: the ESC is manned 24/7/365 and provides support and monitoring for all Interxion facility operations worldwide.

 

Technical specifications

INTERXION LONDON
 
CLIMATE
  • Average temperature: 22°C/72°F with limits of 18°C/64°F and 25°C/77°F
  • Humidity: 50% +/- 10%
  • Redundant air-conditioning
  • Climate control performed according to ETS300019 class 3.1 "Telecom Centers"
  •  
    POWER
  • Diesel generator backup, minimum 16 hours backup
  • 220V AC, 400V AC, UPS 220V AC optional, -48V DC optional
  • Clean earthing and over-voltage protection
  • Dual power feeds individually breakered to each cabinet
  •  
    SECURITY
  • Access: 24 hours a day and 7 days a week
  • Only authorised staff and registered customer staff are allowed on-site
  • Security zones using designated alarm and card-key access
  • Logging of all entries
  • Monitoring of all facilities
  • CCTV with archiving
  •  
    FIRE PROTECTION
  • Gas fire extinguishing system
  • Early warning laser smoke detection (VESDA)
  • Fire-retarding walls (F60)
  •  
    CABLING
  • Power cabling under raised floor
  • Data cabling carried via overhead cable trays
  • Clients

    Busooka

    "We recommend Rack Sense to anybody serious about their business ..."

    News

    28 Apr 2009

    Rack Sense celebrates 5th birthday!

    20 Nov 2008

    Rack Sense adds Telia for network resilience

    17 Mar 2008

    Product refresh with latest Dell enterprise servers

    06 Feb 2008

    News: Rack Sense adds NTT/Verio for network resilience
    Interxion Level(3) AboveNet
     Copyright Rack Sense Ltd © 2002-2016.   All rights reserved.   All pricing excludes VAT @ 20%